Sign In | Join Free | My insurersguide.com
China Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. logo
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.
Active Member

8 Years

Home > CT PT Analyzer >

7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash Disk

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Contact Now

7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash Disk

  • 1
  • 2

Brand Name : GFUVE

Model Number : GF1061-2

Certification : CE, ISO9001

Place of Origin : BEIJING CHINA

MOQ : 1SET

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 200SETS/MONTH

Delivery Time : 2-3weeks

Packaging Details : Standard Export Box

Name : CT PT analyzer

Output voltage : 0-100Vrms

Output current : 0-400 VA (1500 VApeak)

LCD : 7inch TFT touch color LCD

Accuracy : 0.02% or 0.05%

Operating temperature : -10°C to +50°C

Ratio error : 0.02% or 0.05%

Weight : 4KG

Overall dimension (L x W x H) (mm) : 280 x 250 x 160mm

Usage : Measurement CT and Protection CT

Contact Now

0.02% Accuracy 4KG 7Inch LCD CT PT Analyzer for testing CT and PT

GF1061 0.02% Accuracy 4KG 7Inch LCD CT PT Analyzer for testing CT and PT portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.

Features

1. Very Steady and transient state characteristic tests of 90% types of CT/PT

2. The use of advanced power technology, the test knee point reaches up to 30kV,can be customzied to 40KV also.

3. No external other auxiliary equipment, stand-alone to complete all test items

4. CT test, easy to test, all the tests are using the same wire connection except the load test

5. It carries with thermal printer, so it can print test results on site Reference Standard IEC 60044-1-2, ANSI/ IEEE C57.13, IEC61869, GB 1207-2006, GB 1208-2006

6. Parameters such as knee point current and voltage

7. Parameters such as 10% error curve, 5% error curve

8. With battery, working 48hours full load working/

9. The device can store 10000 groups of test data which would not be lost if the device is power off.

10. The data can be displayed and analyzed after the test, or transferred to PC through USB disk and produce a Word file report

11. Portability: weight <4kg, the best light ct analyzer

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity
4. 5% and 10% error curve 4. Ratio error, phase error
5. Accuracy limiting factor (ALF) 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Ratio error, phase error 7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test 
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error

PARAMETERS

Electrical parameters
Accuracy 0.05%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage 0-100Vrms
Output current 0-5Arms (20A peak-value)
Output power 0-400 VA (1500 VApeak)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5%
Secondary winding DC resistance measurement Range 0.1-1000Ω
Accuracy ≤0.05%
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5%±0.1VA
CT/PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed)
Resolution 0.1min
CT ratio error measurement Range 1-50000
Accuracy ≤0.05%
PT ratio error measurement Range 1-10000
Accuracy ≤0.05%
Standards 
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters 
Overall dimension (L x W x H) (mm) 280 x 250 x 160
Weight (kg) ≤4
Environmental conditions 
Relative humidity Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤1000m

Photo

7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash Disk


Product Tags:

transformer test instruments

      

power transformer testing equipment

      
Cheap 7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash Disk for sale

7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash Disk Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)